Setting Up and Adjustments
All ScanStone separators are fitted with a load sensing
system which reduces hydraulic oil working temperatures
thus prolonging the life of components such as pumps,
valves and hoses.
Before fitting the load sensing hose (Fig 3.7.3) the tractor
has to be fitted with a load sensing kit - available from
tractor dealerships along with fitting instructions.
Following fitment of the load sensing kit the load sensing
hose can be connected to the tractor load sensing
coupling.
A simple adjustment should be made at the
Separator PVG control valve - see Open and Closed
Centre hydraulics page 4.3.
If in any doubt as to the type of auxiliary
hydraulic system on the tractor - the operator
should check the tractor manual or consult
his tractor dealership for information.
WARNING
Do not attempt to connect the load sensing
hose to the tractor pressure coupling as this
could result in severe damage to the
windrower’s hydraulic system.