Load Sensing

Setting Up and Adjustments

All ScanStone separators are fitted with a load sensing system which reduces hydraulic oil working temperatures thus prolonging the life of components such as pumps, valves and hoses.

Before fitting the load sensing hose (Fig 3.7.3) the tractor has to be fitted with a load sensing kit - available from tractor dealerships along with fitting instructions.

Following fitment of the load sensing kit the load sensing hose can be connected to the tractor load sensing coupling.

A simple adjustment should be made at the Separator PVG control valve - see Open and Closed Centre hydraulics page 4.3.

If in any doubt as to the type of auxiliary hydraulic system on the tractor - the operator should check the tractor manual or consult his tractor dealership for information.

WARNING
Do not attempt to connect the load sensing hose to the tractor pressure coupling as this could result in severe damage to the windrower’s hydraulic system.